Notice for installation (Multi-point float switch)
Notice for installation (Multi-point float switch)
1.Installation location should be far from water inlet, otherwise the switch may
|
wrongly operate as of water fluctuation, as shown in diagram 1. |
2.If the switch is fixed on the area of concrete pool rim, it should add L type angle |
iron bracket, as shown in diagram 2. |
3.If the switch is fixed in the area of stirring, it is better to install wave tube |
or wave cutter, as shown in diagram 3. |
4.The inner diameter of selected pipe should be larger than the diameter of |
contacting pipe to flange, as shown in diagram 4 |
5.Suggest selecting multi-core cable with 8mm diameter. |
6.Load of controlled circuit must match contact capacity of float switch. |
7.The gravity of tested liquid must be larger than float's and it can’t contain |
magnetic powder such as iron scrap. |
8.The operation point of switch is customized in factory before delivery according |
to the customer requirement. Please do not regulate point personally. |